Look to see if the draft hood over the vent hole is centered and if the legs are straight and secured by screws this may depend on the design of the pipe.
Water heater vent hood sheet metal screws.
The connection between the draft hood and the vent pipe should be secured with sheet metal screws three per connection on a single wall pipe are recommended.
A draft hood must only be connected to an equal or larger sized vent pipe as allowed by code.
Only use the draft hood that is supplied with the water heater.
Draft hood and gas water heater vent pipe connections.
Do not use regular duct tape to secure or seal connections.
Water heater inspection draft hood.
Some adjustments might be needed as long as the original size and shape are kept.
Use three screws per joint.
If the recommended vent pipe diameter is larger than the vent hood opening don t install a reducer.
Residential size water heaters have usually 3 or 4 diameter draft hoods some accept both sizes.
Fasten the flue pipe and fittings together with sheet metal screws.
Some building inspectors don t even allow aluminum tape on joints.
The collar of the draft hood will have a profile that allows for different diameter vent pipes installation picture.
Seal joint at bottom of vent pipe increaser 4 inch vent pipe 3 inch draft hood when two vent pipes are made by different manufacturers they may not fit together.
The size of the vent pipe must not be smaller than the draft hood and connection must be airtight to prevent the leak of the flue gases.
Attach the vent pipe to the draft hood using the sheet metal self tapping screws.
While installing the vent pipe over the draft hood you must secure the connection with the sheet metal screw.
Even if you don t face a fire hazard a single wall vent might for some heaters be too cold and thus the heater might not vent properly in some climates locations.
Water heater draft hood s diameter depends on the size btu s of the appliance.
Cut the pipe to the appropriate length with sheet metal shears.
Snap the new draft hood onto the water heater and secure it with sheet metal screws.
Place furnace tape around the joints to ensure tight seals.
Make sure to have the vent pipe rise vertically at least 12 before installing the elbow.
Turn the water heater thermostat back to the appropriate setting.
Check to see if the draft hood and water heated flue pipe connections are properly secured with sheet metal screws.
Using the flexible gas hose connect the gas control valve on the water heater and the gas supply line.